surge current

French translation: surintensité

GLOSSARY ENTRY (DERIVED FROM QUESTION BELOW)
English term or phrase:surge current
French translation:surintensité
Entered by: Florence Piquemal

15:37 Jan 31, 2023
English to French translations [PRO]
Tech/Engineering - Electronics / Elect Eng / Differential pressure measurement
English term or phrase: surge current
Devices with integrated overvoltage protection must be earthed.
Overvoltage protection:
Nominal functioning DC voltage:
600 V
Nominal discharge current:
10 kA
Surge current check î = 20 kA as per DIN EN 60079-14
Florence Piquemal
France
Local time: 12:19
surintensité
Explanation:
Asker's ST also uses the term 'switch-on current', so the translation must properly reflect the difference between the two phenomena.

'surge current' refers to abnormally high currents that flow - usually owing to a fault in the load or to some external cause (eg: a lightning strike) - some time after the power has been switched on.

Note that a surge is not necessarily 'transient' (a brief 'spike'); a slow but potentially damaging surge may occur, for example, if the system is slowly overloaded, eventually reaching the current level where the surge current limiter is triggered.

Principal source (with a friendly nod to Johannes): my 50-year-old recollections of operating rotating electrical machines (including 25kW / 16kV DC rotary transformers built in the 1920/30s).

See also (amongst others): https://context.reverso.net/traduction/anglais-francais/surg...
Selected response from:

Jennifer Levey
Chile
Local time: 06:19
Grading comment
4 KudoZ points were awarded for this answer



Summary of answers provided
4surintensité
Jennifer Levey
3 +1courant de choc
Marielle Akamatsu
5 -2courant d'appel (courant de surcharge)
Johannes Gleim
4 -1courant de crête
MassimoA
4 -2Le courant d'enclenchement ou courant de choc
Etienne Thems


Discussion entries: 6





  

Answers


5 hrs   confidence: Answerer confidence 4/5Answerer confidence 4/5 peer agreement (net): -2
Le courant d'enclenchement ou courant de choc


Explanation:
Le courant d'enclenchement ou courant d'appel est le nom donné à la surintensité transitoire qui se produit lors de la mise sous tension de certains récepteurs électriques. Ce courant, qui peut atteindre 10 à 50 fois le courant du régime établi, peut requérir d'utiliser des dispositifs de protection adaptés qui permettront le passage de ce courant élevé : fusibles temporisés ou disjoncteurs magnétothermiques spécifiques (accompagnement moteur, courbe D… dont le courant coupé par effet magnétique est très supérieur à celui coupé par effet thermique).

--------------------------------------------------
Note added at 5 heures (2023-01-31 21:32:05 GMT)
--------------------------------------------------

Inrush or Surge currents are a sudden current drawn by a device when first switched on. This surge in current will only last a few cycles of the input power until it returns to a normal state. Often caused by energy storage devices used with mutlifunction decoders.
https://dccwiki.com/Inrush_Current


    https://fr.wikipedia.org/wiki/Courant_d%27enclenchement
Etienne Thems
France
Specializes in field
Native speaker of: Native in FrenchFrench

Peer comments on this answer (and responses from the answerer)
disagree  Jennifer Levey: 'courant d'enclenchement' and 'courant d'appel' are valid answers for Asker's previous question (switch-on current). 'surge current' is a different concept and requires a different term. 'courant de choc' does not appear in your explanation.
40 mins

disagree  Tony M: I agree with Jennifer: this is a different kind of 'surge', not the same as the 'switch-on surge' discussed elsewhere
10 hrs
Login to enter a peer comment (or grade)

20 hrs   confidence: Answerer confidence 4/5Answerer confidence 4/5
surintensité


Explanation:
Asker's ST also uses the term 'switch-on current', so the translation must properly reflect the difference between the two phenomena.

'surge current' refers to abnormally high currents that flow - usually owing to a fault in the load or to some external cause (eg: a lightning strike) - some time after the power has been switched on.

Note that a surge is not necessarily 'transient' (a brief 'spike'); a slow but potentially damaging surge may occur, for example, if the system is slowly overloaded, eventually reaching the current level where the surge current limiter is triggered.

Principal source (with a friendly nod to Johannes): my 50-year-old recollections of operating rotating electrical machines (including 25kW / 16kV DC rotary transformers built in the 1920/30s).

See also (amongst others): https://context.reverso.net/traduction/anglais-francais/surg...

Jennifer Levey
Chile
Local time: 06:19
Specializes in field
Native speaker of: Native in EnglishEnglish
PRO pts in category: 227

Peer comments on this answer (and responses from the answerer)
neutral  Tony M: I think mere 'over-current' is too reductive here. As we are talking about VERY HIGH surge currents (10 kA), I think this really is talking about transient surges of the lightning strike variety.
1 hr
Login to enter a peer comment (or grade)

21 hrs   confidence: Answerer confidence 5/5 peer agreement (net): -2
courant d'appel (courant de surcharge)


Explanation:
Same current type like that asked before, but with different focus, cf. https://eng.proz.com/kudoz/english-to-french/electronics-ele...

Inrush current, input surge current, or switch-on surge is the maximal instantaneous input current drawn by an electrical device when first turned on.
https://dbpedia.org/page/Inrush_current

Inrush current, input surge current, or switch-on surge is the maximal instantaneous input current drawn by an electrical device when first turned on.
https://en.wikipedia.org/wiki/Inrush_current

Le courant d'enclenchement ou courant d'appel est le nom donné à la surintensité transitoire qui se produit lors de la mise sous tension de certains récepteurs électriques. Ce courant, qui peut atteindre 10 à 50 fois le courant du régime établi,
https://fr.wikipedia.org/wiki/Courant_d'enclenchement

Area Electronic tubes / Current, voltage and power
IEV ref 531-16-06
en surge current of an electrode
the peak electrode current under exceptional conditions such as switching-on conditions or fault conditions
fr courant de surcharge d'une électrode, m
valeur de crête du courant d'électrode dans des conditions exceptionnelles telles que l'allumage ou des conditions de défaut
https://www.electropedia.org/iev/iev.nsf/display?openform&ie...

Area Electrical installations / Voltages and currents
IEV ref 826-11-15
en overload current,
overcurrent occurring in an electric circuit, which is not caused by a short-circuit or an earth fault
fr courant de surcharge,

--------------------------------------------------
Note added at 21 hrs (2023-02-01 13:07:17 GMT)
--------------------------------------------------

Area Electrical installations / Voltages and currents
IEV ref 826-11-15
en overload current,
overcurrent occurring in an electric circuit, which is not caused by a short-circuit or an earth fault
fr courant de surcharge,

--------------------------------------------------
Note added at 21 hrs (2023-02-01 13:08:09 GMT)
--------------------------------------------------

Surcharge de courant non répétitive sans tension réappliquée /
No repetive surge current without voltage reapplie
https://docs.rs-online.com/89c1/0900766b8050bfb6.pdf

4.3 Courant de surcharge / Inrush Current
Cette série utilise une thermistance de puissance pour protéger le circuit du courant d'appel.
https://www.digiparts.ch/data/product_datasheets/Manual_MPS2...

limite le courant de surcharge à 1,8 fois la valeur de son calibre.
e-t-a.com
The highest possible overcurrent is limited to 1.8 or 1.5 times rated current.
e-t-a.be

tension d'alimentation maxi 150V - 50/60 Hz - courant de surcharge nominal : 10A - 10s - protection électronique
leroy-somer.com
maximum power supply: 150V - 50/60 Hz - Rated overload current: 10 A - 10 s
leroy-somer.com
https://www.linguee.fr/francais-anglais/search?source=auto&q...

Si un courant de surcharge est appliqué, la fusion commence de préférence au niveau de cette partie plus mince.
If an overcurrent is applied, fusing starts preferably at this thin part.

Le seuil de déclenchement des disjoncteurs thermiques dépend de la valeur du courant de surcharge.
Technology The trip time of thermal circuit breakers depends on the overload current.
https://context.reverso.net/translation/french-english/coura...

Le disjoncteur réenclenchable s'ouvre dans des conditions de courant de surcharge prolongée.
The resettable breaker opens upon prolonged overload current conditions.
https://fr.techdico.com/traduction/francais-anglais/courant ...

Johannes Gleim
Local time: 12:19
Specializes in field
Native speaker of: German
PRO pts in category: 339

Peer comments on this answer (and responses from the answerer)
disagree  Jennifer Levey: If the same ST also refers to 'switch-on surge', then a different term is needed here. And you are confusing 'surge' with 'overload' - again, they're different concepts, with different translations.
58 mins
  -> Courant de surcharge is also proposed. Please read: 'Same current type like that asked before, but with different focus'. Both terms describe the same effect.

disagree  Herbie: Another CL5-Superflop. "Courant d'appel" = pick-up current of a contactor, widely known among electricians
21 hrs
  -> If I, as an electrical engineer, know both terms and their different aspects, I may well use CL 5. And the references support this.
Login to enter a peer comment (or grade)

23 hrs   confidence: Answerer confidence 3/5Answerer confidence 3/5 peer agreement (net): +1
courant de choc


Explanation:
cf.
https://vitrinelinguistique.oqlf.gouv.qc.ca/fiche-gdt/fiche/...
https://patents.google.com/patent/EP2544323A1/fr
https://patents.google.com/patent/EP2544323A1/en

Marielle Akamatsu
France
Local time: 12:19
Native speaker of: Native in FrenchFrench
PRO pts in category: 55

Peer comments on this answer (and responses from the answerer)
agree  Anastasia Kalantzi
3 days 23 hrs
Login to enter a peer comment (or grade)

1 day 21 hrs   confidence: Answerer confidence 4/5Answerer confidence 4/5 peer agreement (net): -1
courant de crête


Explanation:
Le courant crête est l'intensité du courant qu'un circuit absorbe pendant un temps plus ou moins court (et il est supérieur au courant de travail). Cet effet se produit dans certains circuits, lorsqu'une tension leur est appliquée.

MassimoA
Italy
Local time: 12:19
Specializes in field
Native speaker of: Native in ItalianItalian
PRO pts in category: 1

Peer comments on this answer (and responses from the answerer)
neutral  Jennifer Levey: The question is about 'surge', not 'peak'.
2 hrs

disagree  Tony M: That would translate 'peak' current, which is a quite different concept from 'surge' current.
9 hrs
Login to enter a peer comment (or grade)



Login or register (free and only takes a few minutes) to participate in this question.

You will also have access to many other tools and opportunities designed for those who have language-related jobs (or are passionate about them). Participation is free and the site has a strict confidentiality policy.

KudoZ™ translation help

The KudoZ network provides a framework for translators and others to assist each other with translations or explanations of terms and short phrases.


See also:
Term search
  • All of ProZ.com
  • Term search
  • Jobs
  • Forums
  • Multiple search