13:50 Oct 18, 2020 |
German to English translations [PRO] Medical - Medical: Cardiology | |||||||
---|---|---|---|---|---|---|---|
|
| ||||||
| Selected response from: andres-larsen Venezuela Local time: 11:15 | ||||||
Grading comment
|
Discussion entries: 2 | |
---|---|
transmitral flow velocity measurement gives unreliable values Explanation: E/A Ratio - an overview | ScienceDirect Topics www.sciencedirect.com › topics › e-a-ratio Apart from the lower mitral inflow E/A ratio and the diastolic myocardial velocity ... Transmitral flow velocity measurements in horses are relatively unreliable and ... Use and Limitations of E/e' to Assess Left Ventricular Filling ... www.ncbi.nlm.nih.gov › pmc › articles › PMC3259539 Dec 27, 2011 — However, echocardiographic methods can give us unreliable values under ... Mitral inflow velocity (E) correlates well with LV filling pressure in ... JH Park · 2011 · Situations where the use of E/e' may be unreliable | Download ... www.researchgate.net › figure › Situations-where-the-use-... Mitral inflow velocities obtained by pulsed wave Doppler technique and... Mitral ... (ii) unreliable measurement of E velocity (significant mitral regurgitation), (iii) ... A Test in Context: E/A and E/e′ to Assess Diastolic ... www.sciencedirect.com › science › article › pii Mar 21, 2017 — In this paper, we discuss the physiological basis for transmitral flow ... can be unreliable in the setting of incorrect sample volume placement, ... SS Mitter · 2017 · Combined influence of ventricular loading and relaxation on ... www.ahajournals.org › doi › pdf › 01.CIR.78.3.672 The relation of the Doppler transmitral flow velocity profile to left ventricular loading conditions and diastolic properties ... ments of the velocity of blood flow across the mitral valve and, thus ... derivation difficult and unreliable. In the absence of. CY Choong · 1988 · Methods and Reliability of Tissue Doppler Imaging for ... onlinelibrary.wiley.com › doi › full May 19, 2009 — Doppler‐derived transmitral flow velocities are commonly used in humans and small animals for assessment of diastolic LV function and filling ... CC Schwarzwald · 2009 · |
| |
Grading comment
| ||
Login to enter a peer comment (or grade) |
could not be reliably evaluated Explanation: That's what I would say, although my answer could not be reliably evaluated... |
| ||
Notes to answerer
| |||
Login to enter a peer comment (or grade) |
unclear/inconclusive Explanation: unclear/inconclusive finding/result regarding the transmitral flow profile/velocity -------------------------------------------------- Note added at 59 mins (2020-10-18 14:50:53 GMT) -------------------------------------------------- "Nicht sicher verwertbar" is the same as "nicht sicher beurteilbar", in my view. |
| ||
Notes to answerer
| |||